In this example, two partitioned data sets are compared.
Neste exemplo, dois conjuntos de dados particionados são comparados.
//DISKDISK JOB ...
//STEP1 EXEC PGM=IEBCOMPR
//SYSPRINT DD SYSOUT=A
//SYSUT1 DD DSNAME=PDSSET1,UNIT=disk,DISP=SHR,
// DCB=(RECFM=FB,LRECL=80,BLKSIZE=2000),
// VOLUME=SER=111112
//SYSUT2 DD DSNAME=PDSSET2,UNIT=disk,DISP=SHR,
// DCB=(RECFM=FB,LRECL=80,BLKSIZE=2000),
// VOLUME=SER=111113
//SYSIN DD *
COMPARE TYPORG=PO
/*
The control statements are discussed, as follows:
As instruções de controle são discutidas da seguinte forma:
- SYSUT1 DD defines an input partitioned data set, PDSSET1.
The blocked data set resides on a disk volume.
- SYSUT2 DD defines an input partitioned data set, PDSSET2.
The blocked data set resides on a disk volume.
- SYSIN DD defines the control data set, which follows in the input stream.
- COMPARE TYPORG=PO indicates that the input data sets are partitioned.
- SYSUT1 DD define um conjunto de dados particionados de entrada, PDSSET1.
O conjunto de dados bloqueado reside em um volume de disco.
- SYSUT2 DD define um conjunto de dados particionados de entrada, PDSSET2.
O conjunto de dados bloqueado reside em um volume de disco.
- SYSIN DD define o conjunto de dados de controle, que segue no fluxo de entrada.
- COMPARE TYPORG = PO indica que os conjuntos de dados de entrada estão particionados.
Parent topic: IEBCOMPR Examples
© Copyright IBM Corp.
|