JCL z/OS DFSMS - IEBCOMPR Compare Sequential Data Sets-Input Stream and Tape Input



Desenvolvido por DORNELLES Carlos Alberto - Analista de Sistemas - Brasília DF. - cad_cobol@hotmail.com

JCL z/OS DFSMS - IEBCOMPR Example 4: Compare Sequential Data Sets-Input Stream and Tape Input

In this example, two sequential data sets (input stream and tape) are compared.
Neste exemplo, dois conjuntos de dados sequenciais (fluxo de entrada e fita) são comparados.

  //CARDTAPE JOB  ...
  //         EXEC PGM=IEBCOMPR
  //SYSPRINT DD  SYSOUT=A
  //SYSIN    DD  DUMMY
  //SYSUT2   DD  UNIT=tape,VOLUME=SER=001234,LABEL=(,NL),
  //             DCB=(RECFM=FB,LRECL=80,BLKSIZE=2000),
  //             DISP=(OLD,KEEP)
  //SYSUT1   DD  DATA
 
  (input data set)
 
  /*

The control statements are discussed, as follows:
As instruções de controle são discutidas da seguinte forma:

  • SYSIN DD defines a dummy control data set.
    Because no user routines are provided and the input data sets are sequential, utility control statements are not necessary.
  • SYSUT2 DD defines an input data set, which resides on an unlabeled, tape volume.
  • SYSUT1 DD defines a system input stream data set.

  • SYSIN DD define um conjunto de dados de controle fictício.
    Como nenhuma rotina de usuário é fornecida e os conjuntos de dados de entrada são sequenciais, as instruções de controle do utilitário não são necessárias.
  • SYSUT2 DD define um conjunto de dados de entrada, que reside em um volume de fita não rotulado.
  • SYSUT1 DD define um conjunto de dados de fluxo de entrada do sistema.

Parent topic: IEBCOMPR Examples



© Copyright IBM Corp.